single phase dual pump motor water pump controller

Y2 series dual pump control panel , with plastic case ,LCD display ,mainly used in water pumps ,motors and motor equiped devices.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat















Specifications of water pump controller
| Type |
Y2-220V |
| Model |
Y2-4KW-220V |
Y2-7.5KW-220V |
Y2-11KW-220V |
Y2-15KW-220V |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
2.2-15KW |
| Rated Input Voltage |
220+10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Dual pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Level float switch Level probe Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
Working temperature Working humidity Degree of protection Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted IP22 Wall mounting |
| Product Size |
320x220x125mm |
| Package |
Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |














1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3PH=3×0.74KW/PH=2.22KW.
2)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
3)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
4)Can you provide OEM or ODM ?
Yes,we can make the ordes according to your detailed request.
5)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders
0.75-11KW Single-Phase Duplex Submersible Automatic Water Pump Controller

Product Description
Y series is ABS plastic LCD display water pump controller,which can work for both 1-phase and 3-phase up to two pumps.Beside automatic or manual ON/OFF switch,protecting the pump and the pump motor are priorities because a pump failure can have serious consequences.
Y2-220V is a single phase LCD display duplex water pump control box, specifically designed for residential and commercial 240vac pumps. Using high quality import microprocessors, this controller uses our float switch or probes to gain water level signal,as well as electric contact pressure gauge or pressure switch to gain pressure signal.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat















Specifications of water pump controller
| General Specification |
|
|
|
| Type |
Y2-220V |
| Model |
Y2-4KW-220V |
Y2-7.5KW-220V |
Y2-11KW-220V |
Y2-15KW-220V |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
2.2-15KW |
| Rated Input Voltage |
220+10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Dual pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Level float switch Level probe Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
Working temperature Working humidity Degree of protection Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted IP22 Wall mounting |
| Product Size |
320x220x125mm |
| Package |
Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |















1)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
2)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
3)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
1 phase double pump 4kw boat water pump controller
1 phase double pump 7.5kw garden water pump controller
10HP/220V Duplex Water Level Indicator & Pump Control Box


Product Description
Y2-220V is a 1-phase LCD display dual water pump control panel, specifically designed for single phase 220V-240vac pumps. This controller adopts multiple controls as water supply control,drainge control,pressure control and time setting control.Users can manually start/stop a pump,automatically start/stop through water level or pressure signal input,or automatically start/stop by time setting ON/OFF.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat














Specifications of water pump controller
| General Specification |
|
|
|
| Type |
Y2-220V |
| Model |
Y2-4KW-220V |
Y2-7.5KW-220V |
Y2-11KW-220V |
Y2-15KW-220V |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
2.2-15KW |
| Rated Input Voltage |
220+10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Dual pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Level float switch Level probe Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
Working temperature Working humidity Degree of protection Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted IP22 Wall mounting |
| Product Size |
320x220x125mm |
| Package |
Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |



















1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3HP=3×0.74KW=2.22KW.
2)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
3)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
4)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
5)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders
10HP Duplex Single Phase Pump Control with Panel DOL Start

Product Description 10HP Duplex Single Phase Pump Control with Panel DOL Start
Y series are LCD display compact control panels for one or two pumps. They directly connect to pumps up to 22 kW, and feature three-phase and single-phase versions.Y1 is for single pump control while Y2 is for dual pump control.
Dual Pump Operation Mode:
–One duty one standby
–Dual pump alternation in shifts
–Automatic dual pump mutual exchange in faults
–Dual pump simultaneous start
Typical application of 10HP Duplex Single Phase Pump Control with Panel DOL Start
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Sewage pump station
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat













Specifications of 10HP Duplex Single Phase Pump Control with Panel DOL Start
| General Specification |
|
|
|
| Type |
Y2 |
| Model |
Y2-4KW |
Y2-7.5KW |
Y2-11KW |
Y2-15KW |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
2.2-15KW |
| Rated Input Voltage |
230V±10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Double pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Float switch Probe Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Double pump alternate work Automatic restart after power recovery |
Working temperature Working humidity Degree of protection Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted IP54 Wall mounting |
| Product Size |
220x330x135mm |
| Package |
Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |
















1),How can I trust you ?
We have being devoting the pump control panel manufacturing and selling since 2016,now our company has been audited and approved ISO9001 and CE certification.Many pump supplier are using our controller to control and protect their pumps and motors.We can show you our workshop and welcome your visit to our factory.
2),What’s your main market?
Asia/Europe/Middle East/North and south America/Africa etc.
3),How is the payment?
T/T L/C
220V-240VAC Industrial Duplex Water Level & Booster Pressure Pump Controller
Single Phase Intelligent Water Pump Control Protection Box


A2-220V series outdoor rainproof stainless steel controller is for dual pump control system,for reliable control of two pumps in residential or commercial installations up to 18.5kw.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat

Specifications of water pump controller
| Type |
A2-220V |
| Model |
A2-4KW-220V |
A2-7.5KW-220V |
A2-11KW-220V |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
| Rated Input Voltage |
220+10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Dual pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Level float switch
Level probe
Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
Working temperature Working humidity Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted Wall mounting |
| Product Size |
400x300x190mm |
| Package |
Box size:41.5x34x23cm Carton size:71×49.5x43cm PCS/CTN:4 |























1),How can I trust you ?
We have being devoting the pump control panel manufacturing and selling since 2016,now our company has been audited and approved ISO9001 and CE certification.Many pump supplier are using our controller to control and protect their pumps and motors.We can show you our workshop and welcome your visit to our factory.
2),What’s your main market?
Asia/Europe/Middle East/North and south America/Africa etc.
3),How is the payment?
T/T L/C
Single Phase Sewage Pump Household Water Pump Control Box
Product Description
Y2-220V is a single phase LCD display duplex water pump control box, specifically designed for residential and commercial 240vac pumps. Using high quality import microprocessors, this controller uses our float switch or probes to gain water level signal,as well as electric contact pressure gauge or pressure switch to gain pressure signal. For wastewater drainage ,the controller starts from high level,switches the pump off when the water level gets down to the low level.For water supply,the controller starts from low level and switches the pump off when the water level gets up to the high level.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat













Specifications of water pump controller
| General Specification |
|
|
|
| Type |
Y2-220V |
| Model |
Y2-4KW-220V |
Y2-7.5KW-220V |
Y2-11KW-220V |
Y2-15KW-220V |
| Rated Power |
0.75-4KW |
1.1-7.5KW |
1.1-11KW |
2.2-15KW |
| Rated Input Voltage |
220+10%/50Hz or 60Hz |
| Qty.of Controlled Pumps |
Dual pumps |
| Display |
LCD display |
| Signal Transmission Mode |
Level float switch Level probe Pressure switch Electric contact pressure gauge |
| Water Level Indication |
High/Middle/Low |
| Max.Control Distance |
≤2000m without strong electric and electromagnetic fields |
| Over/under-voltage Range |
176V-264V(adjustable) |
| Protections |
Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
| Main Functions |
Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
Working temperature Working humidity Degree of protection Install position |
-25ºC– +55ºC 20%–90%RH, no drips concreted IP22 Wall mounting |
| Product Size |
320x220x125mm |
| Package |
Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |

















1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3HP=3×0.74KW=2.22KW.
2)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
3)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
4)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
5)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders